Data Center Projects: System Planning by APC by Schneider Electric

February 2009 - (Free Research)
The planning sequence described in this paper covers the design of the data center's physical infrastructure layer, whose job it is to house, power, cool, and protect the data center's computing and network functions. 
(WHITE PAPER) READ ABSTRACT |

Essential Standby Generator System Requirements for Next Generation Data Centers by APC by Schneider Electric

January 2005 - (Free Research)
Effective standby generator system installations must address the known problems and challenges relating to current and past designs to ensure high availability. This paper overviews generator system challenges and offers tips on solving them. 
(WHITE PAPER) READ ABSTRACT |

Comparing Data Center Batteries, Flywheels, and Ultracapacitors by APC by Schneider Electric

July 2008 - (Free Research)
This paper explores several popular classes of batteries, compares batteries to both flywheels and ultracapacitors, and briefly discusses fuel cells. 
(WHITE PAPER) READ ABSTRACT |

Ten Cooling Solutions to Support High-Density Server Deployment by APC by Schneider Electric

October 2010 - (Free Research)
High-density servers offer a significant performance per watt benefit. But, depending on the deployment, they can present a cooling challenge. This paper provides ten approaches for increasing cooling efficiency, cooling capacity and power density. 
(WHITE PAPER) READ ABSTRACT |

Fundamental Principles of Network Security by APC by Schneider Electric

July 2009 - (Free Research)
This paper covers the fundamentals of secure networking systems, including firewalls, network topology and secure protocols. 
(WHITE PAPER) READ ABSTRACT |

Understanding Power Factor, Crest Factor, and Surge Factor by APC by Schneider Electric

January 2006 - (Free Research)
This paper explains the technical terms of Power Factor, Crest Factor, and Surge Factor. 
(WHITE PAPER) READ ABSTRACT |

Selecting an Industry-Standard Metric for Data Center Efficiency by APC by Schneider Electric

January 2007 - (Free Research)
This paper explains some of the metrics that have been used to describe the efficiency of data center physical infrastructure and suggests which metric is the most effective. 
(WHITE PAPER) READ ABSTRACT |

Increasing Data Center Efficiency by Using Improved High Density Power Distribution by APC by Schneider Electric

January 2006 - (Free Research)
A new approach to power distribution for high density server installations saves floor space, simplifies power cabling, saves capital cost, reduces weight, and increases electrical efficiency. This paper describes this distribution architecture and quantifies the benefits. 
(WHITE PAPER) READ ABSTRACT |

Understanding EPO and Its Downtime Risks by APC by Schneider Electric

January 2005 - (Free Research)
This white paper describes the advantages and disadvantages of EPO for protecting data centers and small IT equipment rooms containing UPS systems. 
(WHITE PAPER) READ ABSTRACT |

Modular Systems: The Evolution of Reliability by APC by Schneider Electric

January 2005 - (Free Research)
Modularity is an established technique for organizing and simplifying a complex system. In data centers, modular design has already taken root in new fault-tolerant architectures for servers and storage systems. The mission of this paper is to illustrate how modularity delivers a profound reliability benefit: fault tolerance 
(WHITE PAPER) READ ABSTRACT |

Technical Comparison of On-line Vs. Line-interactive UPS Designs by APC by Schneider Electric

January 2004 - (Free Research)
This paper describes the advantages and disadvantages of each topology and addresses some common misconceptions about real-world application requirements. 
(WHITE PAPER) READ ABSTRACT |

A Quantitative Comparison of High Efficiency AC vs. DC Power Distribution for Data Centers by APC by Schneider Electric

January 2007 - (Free Research)
This paper explains why a move to a DC-based architecture is unwarranted on the basis of efficiency by comparing the most efficient DC and AC power distribution methods. 
(WHITE PAPER) READ ABSTRACT |

Ten Errors to Avoid When Commissioning a Data Center by APC by Schneider Electric

February 2009 - (Free Research)
This paper outlines the ten most common errors that prevent successful execution of the commissioning process. 
(WHITE PAPER) READ ABSTRACT |

Watts and Volt-Amps: Powerful Confusion by APC by Schneider Electric

January 2003 - (Free Research)
Knowing the difference between Watts and Volt-Amps (VA) is crucial for UPS load sizing in data centers, but UPS vendors and manufacturers often use the terms interchangeably. Learn how to use these terms correctly in specifying power protection equipment. 
(WHITE PAPER) READ ABSTRACT |

Strategies for Deploying Blade Servers in Existing Data Centers by APC by Schneider Electric

January 2005 - (Free Research)
Installing blade servers in an existing data center stresses the power and cooling systems. This paper reviews five methods to deploy blade servers and avoid common pitfalls, helping you select the best power and cooling approach for your IT shop. 
(WHITE PAPER) READ ABSTRACT |

Determining Total Cost of Ownership for Data Center and Network Room Infrastructure by APC by Schneider Electric

February 2005 - (Free Research)
This white paper describes an improved method for measuring TCO for data center and network room physical infrastructure, and provides examples on how to relate these costs to the overall IT infrastructure and evaluate cost control strategies. 
(WHITE PAPER) READ ABSTRACT |

Preventive Maintenance Strategy for Data Centers by APC by Schneider Electric

February 2009 - (Free Research)
This white paper describes the types of PM services that can help safeguard the uptime of data centers and IT equipment rooms. 
(WHITE PAPER) READ ABSTRACT |

Keep IT Running through Data Center Cooling Outage by APC by Schneider Electric

December 2013 - (Free Research)
This informative white paper talks about some of the trends that are increasing risk of overheating and some of the predictive models and design strategies make it possible to ensure contiuned reliable operation following a power outage. 
(WHITE PAPER) READ ABSTRACT |

Your Roadmap for Data Center Consolidation by APC by Schneider Electric

December 2011 - (Free Research)
This article gives a description of an approach to consolidation that has been successful for a growing number of organizations. The approach responds to a number of problems that typically arise when consolidating into an existing data center. 
(WHITE PAPER) READ ABSTRACT |

The Different Technologies for Cooling Data Centers by APC by Schneider Electric

December 2012 - (Free Research)
This white paper talks about data center cooling and the advantages, disadvantages and applications of the 13 basic methods for heat removal. 
(WHITE PAPER) READ ABSTRACT |

Data Center Evaluation: Your Electrical Meter Options by APC by Schneider Electric

December 2013 - (Free Research)
This white paper outlines the different types of meters and their applications/benefits in certain situations. 
(WHITE PAPER) READ ABSTRACT |

Fundamental Principles of Generators for Information Technology by APC by Schneider Electric

November 2011 - (Free Research)
This whitepaper covers the basics on standby generators and systems to prepare your IT staff for any prolonged utility power outages. 
(WHITE PAPER) READ ABSTRACT |

Types of Prefabricated Modular Data Centers by APC by Schneider Electric

November 2013 - (Free Research)
This whitepaper proposes a framework for removing the ambiguity in the naming of preassembled data center systems and subsystems. 
(WHITE PAPER) READ ABSTRACT |

Specification of Modular Data Center Architecture by APC by Schneider Electric

November 2012 - (Free Research)
This white paper gives a definition to the idea of the modular data center. 
(WHITE PAPER) READ ABSTRACT |

High Efficiency Indirect Air Economizer-based Cooling for Data Centers by APC by Schneider Electric

November 2013 - (Free Research)
This white paper details how indirect air economizer-based cooling will lower the cost of running your data center without the same risk as directly exposing your infrastructure to the outdoor air. 
(WHITE PAPER) READ ABSTRACT |

1 - 25 of 120 | Next Page

Advertisement

Search FindTech

Search the
Technology Services Directory
  The Complete KnowledgeStorm Network of Technology Search Sites. Focused searching for faster results.

TechTarget provides enterprise IT professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective IT purchase decisions and managing their organizations' IT projects - with its network of technology-specific Web sites, events and magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Reprints




  TechTarget - The IT Media ROI Experts